Provide waveform recording function options, record waveform changes, easily replay waveform, find out the fault location. Multi level gray level display capability, providing similar fluorescent display effect, and the change of waveform can be seen at a fraction of a millisecond. Data Sheet. Product Information.
Hardware Waveform Recording and Playback Function Provide waveform recording function options, record waveform changes, easily replay waveform, find out the fault location.
Digital Fluorescent Display Gray level display capability, similar to fluorescent display effect, with minute change of waveform. Mixed Signal Analysis Capability The plus model provides 16 digital logic channels, which makes it more convenient to test multiple analog and digital signals at the same time and analyze logic signals more conveniently. Two 25MHz Signal Sources With two 25MHz arbitrary waveform generator models, the oscilloscope, logic analyzer and signal source are combined to give you a more efficient test experience.
Send Email. Discrete The parameter could be any of the values listed. The oscilloscope will automatically adjust the vertical scale, horizontal timebase and trigger mode according to the input signal to realize optimum waveform display. This command is equivalent to pressing the AUTO key at the front panel. Description Set or query the memory depth of the oscilloscope namely the number of waveform points that can be stored in a single trigger sample.
The default unit is pts points. Description Set or query the acquisition mode when the oscilloscope samples. Description Query the current sample rate. Description Set or query the coupling mode of the specified channel.
Description Set or query the vertical offset of the specified channel. The default unit is V. Description Set or query the delay calibration time of the specified channel to calibrate the zero offset of the corresponding channel. The default unit is s. Description Set or query the vertical scale of the specified channel. Description Set or query the amplitude display unit of the specified channel.
Description Set or query the channel source of the manual cursor measurement mode. Description Set or query the horizontal position of cursor A in the manual cursor measurement mode. Description Set or query the vertical position of cursor B in the manual cursor measurement mode.
Description Query the Y value of cursor B in the manual cursor measurement mode. The unit depends on the vertical unit currently selected. Return The query returns the Y value of cursor B in scientific notation.
Description Set or query the channel source of cursor A in the track cursor measurement mode. Description Set or query the horizontal position of cursor A in the track cursor measurement mode. Description Query the vertical position of cursor B in the track cursor measurement mode.
The pixel coordinate of the screen ranges from 0,0 to , Description Query the Y value of cursor B in the track cursor measurement mode. The unit is the same as the channel unit currently selected. Description The auto cursor function can measure 24 waveform parameters. Using this command, you can select the parameters to be measured by the auto cursor from the five parameters enabled last or query the parameters currently measured by the auto cursor.
Description Set or query the vetical position of cursor A in the XY cursor measurement mode. The unit depends on the amplitude unit of the corresponding channel.
Return The query returns the Y value of cursor A in scientific notation. Description Read the bitmap data stream of the image currently displayed. The instrument responds to the command and directly returns the bitmap data stream of the image currently displayed to the buffer area of the PC.
Description Set or query the display mode of the waveform on the screen. Description Set or query the grid type of screen display. HALF: turn the background grid off. Page Ieee Page Esr The query returns an integer between 0 and Description Query the ID string of the instrument.
Description Query the event register for the status byte register. The value of the status byte register is set to 0 after this command is executed. Explanation The bit 0 and bit 1 of the status byte register are not used and are always treated as 0. Note: The operations can be divided into two types. Description Enable or disable the math operation function or query the math operation status.
Description Set or query the source of the math operation. Description Set or query the vertical offset of the operation result. The unit depends on the operator currently selected and the unit of the source. Description Set or query the window function of the FFT operation. Description Set or query the vertical unit of the FFT operation result. Description Set or query the center frequency of the FFT operation result, namely the frequency relative to the horizontal center of the screen.
The default unit is Hz. Parameter Name Description Set or query the end point of the waveform math operation.
0コメント